Choosing a test chart

Which chart to buy or print depends on what you need to measure, how much of the field of view you need to cover, and how much room the test stand has. This article is a starting point; the module documentation for the version you are running has the detail.

Start from the measurement

You want to measure Look at
Sharpness across the frame, plus tonal response and color in one shot SFRplus, eSFR ISO
Sharpness only, with a chart that tolerates being photographed at an angle SFRreg
Sharpness with the densest set of edges for a given chart area Checkerboard
Color accuracy and tonal response on their own Colorchecker 24, or a step chart
Distortion and field of view A dot pattern or a grid

SFRplus and eSFR ISO both measure several image quality factors from one capture, which is usually what makes a test efficient: one exposure, one analysis, several numbers.

Then check it fits

A chart has to fill enough of the frame for the features to be resolved, and it has to be lit evenly. Two practical limits decide most choices:

Printed or transmissive

A printed reflective chart is cheaper and easier to light, and its contrast is limited by the paper: enough for sharpness and color, not enough for dynamic range. A transmissive chart on a light box reaches much higher contrast, which is what dynamic range measurements need.